  • This study aims to enable the quantitative application of mechanoluminescent materials in shock wave overpressure measurement. Existing quasi-static or low-frequency dynamic calibration methods fail to accommodate the transient loading characteristics of shock waves. To address this issue, the authors conducted a dynamic calibration study on ZnS:Mn2+ mechanoluminescent composite films. The authors prepared ZnS:Mn2+ powder via a high-temperature solid-state method and fabricated it into composite films. They established a shock-tube dynamic calibration system to synchronously acquire shock wave overpressure signals, mechanoluminescence images and spectra. They also proposed a mechanoluminescence intensity extraction method, with the standard light source method and spectral matching method as core components. Sixty calibration experiments were conducted at overpressures ranging from 0.1 to 2.0 MPa. The results showed that, for the film, the peak mechanoluminescence intensity exhibited a strong linear relationship with peak overpressure from 0.2 to 1.7 MPa. The calibration equation was Ipeak= 44.702 Ppeak + 15.052, with a coefficient of determination of 0.9933 and a linearity error of 5.81 percent. The film exhibited a sub-millisecond time-domain dynamic response, with a response latency of approximately 0.174 ms and a rise time of approximately 0.323 ms. Under repeated loading, irreversible mechanoluminescence degradation occurred, and the degree of degradation increased with rising peak overpressure. These calibration results demonstrate the feasibility of inverting shock wave peak overpressure from mechanoluminescence intensity, and provide an experimental basis for the application of mechanoluminescent materials to full-field visual measurement of shock wave overpressure.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views(78) PDF downloads(6) Cited by()
    Proportional views
    Related
    

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return